π₯ GasFitters.caPRO GAS FITTING SUITE β POWERED BY EYESPYRβ’
B149.1 Β· IFGC Β· CSA Z662
Technical Safety BC
EyeSpyRβ’ Verified
πJOB INFORMATION
π₯ GAS SYSTEM CONFLICT
π§WORK ITEMSBC PRICING 2026
Gas Lines
Appliances
Furnace/Boiler
Labour
Misc/Parts
Β½" Black Iron $4.50/ft
ΒΎ" Black Iron $6.80/ft
1" Black Iron $9.20/ft
CSST Β½" $7.50/ft
CSST ΒΎ" $10.80/ft
Shutoff Β½" $38
Shutoff ΒΎ" $52
Drip Leg $45
CSST Bond $95
Pressure Test $180
| Description | Unit | Qty | Unit $ | Total |
|---|
Range Conn. $185
Dryer Conn. $165
Fireplace $420
BBQ Outlet $280
Pool Heater $650
Generator $850
Flex & Test $55
| Description | Unit | Qty | Unit $ | Total |
|---|
Furnace Swap $1,850
Furnace 100K $2,200
Tankless WH $2,800
Tank WH $1,100
Boiler $3,800
Unit Heater $1,200
Type B Vent $18/ft
Conc. Vent $220
| Description | Unit | Qty | Unit $ | Total |
|---|
Journeyman $115/hr
Apprentice $68/hr
TSB Permit $320
FortisBC Insp. $175
Combustion Air $145
Emergency $380
| Description | Unit | Qty | Unit $ | Total |
|---|
CO Alarm $85
Pipe Dope $18
Hangers $22
Fittings $65
| Description | Unit | Qty | Unit $ | Total |
|---|
π₯ All work performed under B149.1 Natural Gas and Propane Installation Code, CSA Z662, and Technical Safety BC permit requirements. GST (5%) and BC PST (7%) applied per BC regulations.
π₯ ESTIMATE SUMMARY
Gas Lines$0.00
Appliances$0.00
Furnace/Boiler$0.00
Labour$0.00
Misc/Parts$0.00
Subtotal$0.00
MARKUP20%
Markup$0.00
GST (5%)$0.00
BC PST (7%)$0.00
TOTAL ESTIMATE
$0.00
β οΈ Valid 30 days. Subject to site conditions. Permit required β Technical Safety BC.
QUICK STATS
Line Items0
Materials$0.00
Labour$0.00
Mat/Labour Ratioβ
Gross Margin0%
π₯GAS PIPE SIZINGIFGC/IRC Β· LONGEST RUN METHOD
π Longest Run Method per IFGC/IRC and B149.1. Always verify with local AHJ and Technical Safety BC.
π PIPE CAPACITY TABLE β BTU/hr Γ 1000
Schedule 40 Steel Β· Natural Gas Β· 0.5 PSI inlet Β· 0.3" W.C. drop
| Length | Β½" | ΒΎ" | 1" | 1ΒΌ" | 1Β½" | 2" | 2Β½" | 3" |
|---|---|---|---|---|---|---|---|---|
| 10' | 175 | 360 | 680 | 1400 | 2100 | 3950 | 6300 | 11000 |
| 20' | 120 | 250 | 465 | 950 | 1460 | 2750 | 4350 | 7700 |
| 30' | 97 | 200 | 375 | 770 | 1180 | 2200 | 3520 | 6250 |
| 40' | 82 | 170 | 320 | 660 | 990 | 1900 | 3000 | 5300 |
| 50' | 73 | 152 | 285 | 580 | 890 | 1680 | 2650 | 4700 |
| 60' | 66 | 138 | 260 | 530 | 810 | 1520 | 2400 | 4300 |
| 80' | 57 | 118 | 220 | 450 | 690 | 1300 | 2050 | 3700 |
| 100' | 50 | 103 | 195 | 400 | 610 | 1150 | 1850 | 3250 |
| 150' | 40 | 84 | 157 | 320 | 490 | 925 | 1480 | 2650 |
| 200' | 35 | 72 | 135 | 275 | 420 | 800 | 1270 | 2280 |
| 300' | 28 | 58 | 110 | 225 | 340 | 640 | 1030 | 1820 |
π¨COMBUSTION AIR CALCIFGC Β§304 Β· B149.1
π COMBUSTION AIR QUICK REFERENCE
| Method | Requirement | Opening |
|---|---|---|
| Indoor (Standard) | 50 cu.ft. / 1K BTU | β |
| Indoor (Tight) | 21 cu.ft. / 1K BTU | β |
| Outdoor Direct/Vert. | Two openings req'd | 1 sq.in./4K BTU ea. |
| Outdoor Horiz. Duct | Two openings req'd | 1 sq.in./2K BTU ea. |
| Mechanical Supply | 1 CFM / 2,400 BTU | Interlock req'd |
β οΈ High opening within 12" of ceiling Β· Low opening within 12" of floor Β· Min. 100 sq.in. each Β· Direct vent appliances do NOT require combustion air openings Β· Always verify with AHJ
GAS SUPPLY
Gas Meter
Service entry
Regulator
Pressure control
APPLIANCES
Furnace
100K BTU
Water Heater
40K BTU
Tankless WH
199K BTU
Range/Oven
65K BTU
Fireplace
40K BTU
BBQ Outlet
60K BTU
Pool Heater
400K BTU
PIPE TYPE
Black Iron
Schedule 40
CSST Flex
Corrugated SS
π₯ BTU SUMMARY
0
TOTAL BTU/hr
π AUTO MATERIALS
// Place appliances
// to auto-populate...
// to auto-populate...
SKETCH EST.$0.00
π·NANO BANANA EQUIPMENT SCANGemini 3.1 Flash Vision Β· AI Appliance Analysis
WHAT IT DOES
πΈ Snap a photo of the appliance data plate
π Reads BTU, model, serial, gas type
β οΈ Detects improper venting or recalled models
π Adds BTU straight to pipe sizing calc
π‘οΈ EyeSpyRβ’ photo attached to invoice
π Reads BTU, model, serial, gas type
β οΈ Detects improper venting or recalled models
π Adds BTU straight to pipe sizing calc
π‘οΈ EyeSpyRβ’ photo attached to invoice
SAFETY LOCKDOWN TRIGGERS
π¨ Improper venting detected
π¨ Missing drip leg on appliance
π¨ Recalled appliance model flagged
π¨ CO risk from unvented appliance
β οΈ Over-BTU for existing pipe size
π¨ Missing drip leg on appliance
π¨ Recalled appliance model flagged
π¨ CO risk from unvented appliance
β οΈ Over-BTU for existing pipe size
π·
Snap or Upload Appliance Data Plate
JPG, PNG β Furnace/WH nameplate, gas meter tag, or equipment schedule
βοΈDEMO: SIMULATE APPLIANCE SCAN
πDOCUMENT READERAuto-Extract BTU from Specs/Blueprints
π
Drop files here or click to upload
PDF, Images (JPG/PNG), Text files β Extracts BTU ratings automatically
π°PROGRESS BILLINGTotal: $0.00
$0.00
COLLECTED
$0.00
NEXT DUE
$0.00
REMAINING
β
Deposit β 25%
Trigger: Contract signed Β· Before work begins
$0.00
25%
π₯
Rough-In / Pressure Test β 35%
Trigger: TSB rough-in inspection passed Β· Pressure test certified
$0.00
35%
π§
Appliances Connected β 25%
Trigger: All appliances connected, lit off, combustion tested
$0.00
25%
πΈ
Final + EyeSpyRβ’ Photo β 15%
Trigger: TSB final sign-off Β· EyeSpyRβ’ photo of permit + meter attached to QBO invoice
$0.00
15%
πQUICKBOOKS ONE-CLICK SYNCPRO $10/mo
π EyeSpyRβ’ Verification photo (permit card + meter tag) auto-attached to every QBO invoice. Audit trail for Technical Safety BC compliance.
ACCOUNT MAPPING
π³CLIENT PAYMENT β PAYPALCAD Β· GST + PST INCLUDED
βοΈ ONE-TIME SETUP
Enter your PayPal Business email. Saved locally β never sent to any server.
INVOICE DETAILS
Clientβ
Estimate #β
Subtotal$0.00
GST 5%$0.00
BC PST 7%$0.00
TOTAL (CAD)$0.00
COLLECT MILESTONE
CHARGING
$0.00
Select milestone above
π Payment processed by PayPal. Ref: β. All work under B149.1 and Technical Safety BC permit requirements.
πPAYMENT LOG
No payments logged yet.
πREFERENCE TABLES
π₯ COMMON APPLIANCE BTU RATINGS
| Appliance | BTU Range | Notes |
|---|---|---|
| Gas Range/Oven | 40,000β65,000 | Residential |
| Tank Water Heater 40gal | 32,000β40,000 | Standard |
| Tank Water Heater 50gal+ | 36,000β76,000 | High recovery |
| Tankless Water Heater | 150,000β199,000 | Whole house |
| Furnace Residential | 60,000β120,000 | Most homes |
| Furnace Large Home | 100,000β200,000 | 2500+ sq ft |
| Boiler Residential | 75,000β150,000 | Hydronic |
| Gas Fireplace | 20,000β40,000 | Decorative |
| Gas Dryer | 20,000β25,000 | Residential |
| Pool Heater | 200,000β400,000 | In-ground |
| BBQ Grill Built-in | 25,000β100,000 | Outdoor |
| Generator Standby | 150,000β500,000 | Whole house |
π FITTING EQUIVALENT LENGTHS (ft)
| Fitting | Β½" | ΒΎ" | 1" | 1ΒΌ" | 1Β½" | 2" |
|---|---|---|---|---|---|---|
| 90Β° Elbow | 1.5 | 2.0 | 2.5 | 3.5 | 4.0 | 5.0 |
| 45Β° Elbow | 0.8 | 1.0 | 1.3 | 1.8 | 2.0 | 2.5 |
| Tee (Run) | 1.0 | 1.3 | 1.8 | 2.3 | 2.5 | 3.5 |
| Tee (Branch) | 3.0 | 4.0 | 5.0 | 7.0 | 8.0 | 10.0 |
| Ball Valve | 0.2 | 0.3 | 0.4 | 0.5 | 0.6 | 0.8 |
β‘ NATURAL GAS vs PROPANE
| Property | Natural Gas | Propane (LP) |
|---|---|---|
| BTU per cu.ft. | ~1,000 | ~2,500 |
| Specific Gravity | 0.60 | 1.52 |
| Supply Pressure | 0.25β0.5 PSI | 11" W.C. |
| Pipe Sizing Factor | 1.0 (baseline) | ~1.5Γ capacity |
| Odourant | Mercaptan added | Ethyl mercaptan |